Caterpillar 3512 Genset 1250KW
The Caterpillar Power Package is housed in 40FT Enclosure. Equipped with heating system and lighting equipment.
- Manufacture: Caterpillar
- Model: 3512
- Housed in a 40FT Enclosure
- Standby Rating: 1250 kW
- Continuous Duty: 1000 KW
- Generator: Caterpillar 2 Bearing SR4 Generator
- Voltage: 4160/2400 volts
- Genset Frequency: 60 HZ,
- Hours: Only 7611 hours of operation since total rebuild by Finning Cat.
- Has been serviced and maintained by Caterpillar Dealer.
- Utility grade Synchronizing Switchgear
- External Radiator,
- This package is set up for Remote Operations.
- Equipped with a heating system and lighting equipment for cold weather conditions.
- Caterpillar 3512 Genset 1250KW in Very Good Condtion
GENERATOR SET SPECIFICATIONS
Maximum Rating | 1250 ekW |
Minimum Rating | 890 ekW |
Emissions/Fuel Strategy | Low Fuel Consumption |
Voltage | 380 to 13800 Volts |
Frequency | 60 Hz |
Speed | 1800 rpm |
Duty Cycle | Standby, Mission Critical, Prime, Continuous |
ENGINE SPECIFICATIONS
Engine Model | 3512 TA, V-12, 4-Stroke Water-Cooled Diesel |
Bore | 6.69 in |
Stroke | 7.48 in |
Displacement | 3161.03 in³ |
Compression Ratio | 13.5:1 |
Aspiration | TA |
Fuel System | Direct Unit Injection |
Governor Type | Woodward |
3512 (60 HZ) STANDARD EQUIPMENT
AIR INLET SYSTEM
- Air cleaner; single element canister type with service indicator
AIR INLET
- Air Cleaner
COOLING
- Radiator fan and fan drive
- JWAC.
EXHAUST
- Exhaust flange outlet
- Dry Exhaust Manifold
FUEL
- Secondary fuel filter
- Primary fuel filter with integral water separator
- Fuel cooler; not included with packages without radiator
- Secondary fuel filters
- Fuel priming pump
GENERATOR
- IP23 Protection
- Matched to the performance and output characteristics of Cat engines
POWER TERMINATION
- Bus Bar
CONTROL PANEL
- Accessory module data link
- Features include:
- Over / under voltage (27 / 59)
- Coolant temperature
- Generator phase sequence
- Serial annunciator module data link
- Low coolant temperature
- Low oil pressure
- DC volts
- Over / Under voltage (27/59)
- Auto/start/stop control
- Exciter diode monitor
- Failure to start (overcrank)
- 6 programmable digital inputs
- Emergency stop
- Generator mounted – rear facing
- Programmable protective relaying functions:
- Power factor (per phase & average)
- Alarm acknowledge
- DC volts
- kVA (per phase, average & percent)
- Overspeed
IVR includes:
- RFI suppression
- Emergency stop pushbutton
- Package mounted radiator (except C175)
- Overspeed
- Emergency stop
- kVAr (per phase, average & percent)
- Environmental sealed front face
- Customer data link (Modbus RTU)
- Min / max exciter limiter
- Speed adjust
- Operating hours
- True RMS AC metering, 3-phase, +/-2% accuracy
- Reactive droop capability
Customizable screens
- Volts (L-L & L-N)
- PLC functionality
- Digital indication for:
- RPM
- High coolant temperature
- Digital indication for:
- kW-hr (total)
- Over / under frequency (81 o / u)
- Low coolant temperature
- 24 Volt DC operation
- kW-hr (total)
- Oil pressure (psi, kPa or bar)
- Warning/shutdown with common LED indication of shutdowns for:
- kVAr-hr (total)
- EMCP 4.2B
- 2 Programmable relay outputs (Form C)
- kVAr-hr (total)
- kW (per phase, average & percent)
- kVAr (per phase, average & percent)
- Engine cool-down timer
- Over / Under frequency (81 o/u)
- Engine cool-down timer
- True RMS AC metering, 3-phase, +/-2% accuracy
- Low coolant level
- Frequency (Hz)
- Controls:
- Generator phase sequence
- High coolant temperature
Communications:
- Reverse Power (kW) (32)
- Volts (L-L & L-N), frequency (Hz)
- Alarm acknowledge
- Environmental sealed front face
- Controls:
- Operating hours
- Generator mounted – rear facing
- Power Factor (per phase & average)
- kW (per phase, average & percent)
- Programmable protective relaying functions:
- Engine cycle crank
- Reverse Power (kW) (32)
- 24-volt DC operation
- Lamp test
- Text alarm / event descriptions
- Failure to start (overcrank)
- Generator set packages include Caterpillar’ s Voltage Regulator (IVR)
- Warning / shutdown with common LED indication of shutdowns for:
- Text alarm / event descriptions
- 4 programmable relay outputs (Form A)
- Lamp test
Load histogram feature
- Coolant temperature
- Auto / start / stop control
- Overcurrent (50 / 51)
- kVA (per phase, average & percent)
- KVAR/PF modes
- Engine cycle crank
- 3 Phase voltage sensing
- 2 Programmable digital outputs
- Low oil pressure
- Reverse Reactive Power (kVAr) (32RV)
- EMCP 4 Genset Controller
- RPM
- Oil pressure (psi, kPa or bar)
- Amps (per phase & average)
- Low coolant level
- Amps (per phase & average)
- EMCP4.2 controller including:
COOLING SYSTEM
- Radiator fan and fan drive
- Fan and belt guards
- JWAC
- Caterpillar Extended Life Coolant
- Coolant level sensors
- Coolant drain line with valve
EXHAUST SYSTEM
- Dry Exhaust Manifold.
- Exhaust flange outlet(s)
FUEL SYSTEM
- Fuel cooler; not included with packages without radiator
- Flexible fuel lines – shipped loose
- Secondary fuel filters
- Fuel priming pump
GENERATORS AND ATTACHMENTS
- LV:
- Winding temperature detectors
- 3 phase brushless, salient pole
- 1800 Frames are form wound, permanent magnet, with winding temperature detectors
- NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime/150C standby)
- Generator set packages include Caterpillar’s Digital Voltage Regulator (CDVR)
- CDVR includes reactive droop capability, 3-phase voltage sensing, KVAR/PF modes, RFI suppression, min/max exciter. Limiter and exciter diode monitor
- 6 lead
- Internal Excitation
- Busbar connections, top center mounted, top cable entry. 50 Hz models: IEC standard hole pattern
- Random wound
GOVERNING SYSTEM
- Woodward 2301A isochronous governor
LUBE SYSTEM
- Integral lube oil cooler
- Oil filter, filler and dipstick
- Oil drain lines and valve
- Fumes disposal
- Gear type lube oil pump.
- Lubricating oil.
MOUNTING SYSTEM
- Rubber anti-vibration mounts (shipped loos
- Rails – engine/generator/radiator mounting
STARTING / CHARGING SYSTEM
- Battery disconnect switch
- Battery and battery rack w/cables
- 24-volt electric starting motor
GENERATOR AND ATTACHMENTS
- Random wound
- LV:
- 6 lead
- 3 phase brushless, salient pole
GENERAL
- Right hand servicing
- Caterpillar Yellow with high gloss black rails & radiator
- Flywheel and Flywheel housing-SAE No. 00
- SAE Standard Rotation
- Paint – Caterpillar Yellow except rails and radiators gloss black
Visit our other inventory
Overview
- Category : Diesel
- Item Number : H202
- Offer Type : For Sale
- Quantity : 1
- Electrical Output : 1250 KW
- Type of Equipment : Reciprocating
- Manufacture : Caterpillar
- Model : 3512
- Application : Industrial
- Rating : Standby
- Fuel Type : Diesel (LFO)
- Hours of Operation : 7611
- Condition : Used
- Alternator : Caterpillar
- Frequency : 60 HZ
- Voltage : 4160/2400 volts
- Phase : 3
- Mounted Type : Containerized Sound Attenuated
- Enclosure Certification : CSC, ISO, CE
- Fuel Tank : Yes
- Operational on Inspection : Yes